Existing a few models of SCENAR. Most popular model - CHANS-SCENAR, cheapest model - CHANS-SCENAR-02, best professional model - SCENAR-1-NT version 01
CHANS-Scenar (Home Device)- "Family doctor" devices.
CHANS-SCENAR is a particular version of the device that can be used at home and in any other conditions (on a business trip or a journey, in a car, in a plane, etc.) to alleviate the pain, to treat respiratory diseases, relieve from problems at traumas, burns, frostbites.
Medical personnel can use this device to treat any diseases.
Ease of operation, reliability in service and high effectiveness of CHENS-SCENAR devices make them indispensable in first aid rendering.
You may use CHANS-SCENAR:
-
to treat home traumas (wounds, abrasion, scratches, soft tissue bruises, muscle strains, sprains, I and II degree burns and frostbites);
-
to alleviate or eliminate aches and pains of well-known origin (headache, toothache, radiculitis pain, menstrual pain, as well as pains in oncological patients – to improve life quality);
-
to treat crush syndrome, intoxication, wounds when different accidents occur (until qualified medical care is provided);
-
for normalization of sleep;
-
for blood pressure normalization;
-
to treat acute respiratory diseases and viral respiratory infections;
-
for decongestion (edema removal);
-
to help out of a shock, faint, heart attack (until qualified medical care is provided);
-
for cosmetic treatment (face-lifting, wrinkle removal, skin aging prophylaxis).
Under doctor's guidance you can use CHANS-SCENAR devices to treat:
-
nervous system;
-
musculoskeletal system;
-
respiratory system; - cardiovascular system;
-
cardiovascular system;
-
digestive apparatus;
-
urogenital system;
-
tooth diseases
as well as:
-
for prophylaxis of adverse reaction to drugs;
-
for prophylaxis of postvaccinal complications in children and adults;
-
to associate chemo- and radiotherapy in cancer patients.
In various cases (i.e. for various diseases) different frequency values can be optimal. The frequencies ranging from 60 to 90 Hz are the most optimal.
That is why basic model has one "universal" frequency - 90 Hz, and the frequency modulation mode - from 30 to 120 Hz, i.e. "oscillating" frequency. And this is enough for lay users to achieve the desired effect.
Version 01 can also operate at frequencies of 14, 60, 320 Hz, what expands its field of application.
Light version 02 has no the "oscillating frequency", but it has another operating frequency - 60 Hz - that is actuated simultaneously with dosing mode.
The main therapeutic effect of all the devices is practically the same. The devices differ only by their extra options.
Great potentials can give a faster effect but to achieve it you should learn to use them properly.
Add-on probes can be connected both to the CHANS-SCENAR devices and to professional SCENAR-devices.
Please, see summary table of parameters:
Characteristics
|
Basic model
|
Version 01 and 01M
|
Version 02
|
Appearance |
|
|
|
Frequency | 90 | 14, 60, 90, 320 | 90, 60 |
Amplitude modulation | 3:1 | 3:1 | Combined with 60 Hz |
Frequency modulation | 30-120 | 30-120 | - |
Dosed mode | For any modes and their possible combinations | For any modes and their possible combinations CHANS 01M has LCD and more friendly interface |
Combined with 60 Hz, 3:1 |
SCENAR-NT
It is a line of professional devices with a great medical potential, reliability in operation, and a capability to display a large amount of information. The devices are designed for professional application by general practitioners in outpatient departments, ambulance, as well as at home.
"SCENAR-1-NT" version 01
Specifications:
-
influencing impulse frequency is selected in the range from 15 to 350 Hz;
-
“frequency modulation” mode, the range is 30 to 120 Hz;
-
intermittent pulse trains with duration from 1 to 5 sec with the time gap of 1 sec;
-
4 modes of influencing pulse waveform modification (“damping”);
-
variable pulse waveform (variable damping – var “damping”);
-
“intensive therapy” mode (influencing by impulse packets, the number of impulses in a packet is from 1 to 8);
-
duration of gaps (including variable gaps) between the impulses in each packet can be changed;
-
combined modulation mode (“swing”);
-
several modes of time-dosed high-amplitude influence (a single packet of from 1 to 8 high amplitude impulses) (“like a bee sting” – BEE mode)
-
2 screening modes; the mode of acupuncture points electroconductivity measuring at alternating current;
-
two algorithms of influence dosing;
-
graphic display of the current reaction dynamics and velocity of its change;
-
a special power decreasing mode for overly sensitive individuals and for treatment of mucous membranes and open wounds;
-
data display on a graphic LCD with backlight;
-
up to 5 different programs can be saved;
-
built-in stop-watch.
"SCENAR-1-NT" version
02
Three modifications of the version are available.
Specifications:
-
influencing impulse frequency is selected in the range from 15 to 350 Hz;
-
“frequency modulation” mode, the range is 30 to 120 Hz;
-
intermittent pulse trains with duration from 1 to 5 sec with the time gap of 1 sec;
-
4 modes of influencing pulse waveform modification (“damping”);
-
the mode of variable pulse waveform (variable damping – var);
-
"intensive therapy" mode (influencing by impulse packets, the number of impulses in a packet is from 1 to 8);
-
duration of gaps (including variable gaps) between the impulses in each packet can be changed (“Z” submode);
-
combined modulation mode (“swing”);
-
1 screening mode;
-
two algorithms of influence dosing;
-
a special power decreasing mode for overly sensitive individuals and for treatment of mucous membranes and open wounds;
-
data display on a graphic LCD with backlight;
-
up to 5 different programs can be saved;
-
built-in stop-watch.
"SCENAR-1-NT" version 03
Specifications:
-
4 influencing impulse frequencies 15, 60, 120 and 350 Hz;
-
“frequency modulation” mode, the range is 30 to 120 Hz;
-
intermittent pulse trains with duration of 3 sec and the time gap of 1 sec;
-
one algorithm of influence dosing;
-
graphic display of the current reaction dynamics and velocity of its change;
-
data display on a graphic LCD with backlight.
"SCENAR-2-NT"
Specifications:
-
two influencing impulse frequencies 60 and 120 Hz;
-
“frequency modulation” mode, the range is 30 to 120 Hz;
-
saw-tooth amplitude modulation;
-
one algorithm of influence dosing;
capability to estimate reaction values and reaction coefficient according to the LED indicators states;
Please, see summary table of parameters:
Device parameters, versions
|
SCENAR-2-NT
|
SCENAR-1-NT
|
|||||
03
|
02
(Variant 3)
|
02
(Variant 2)
|
02
(Variant 1)
|
01(V0) |
01
|
||
Diagnostics: EPD |
-
|
-
|
-
|
-
|
-
|
+ |
+
|
IDM
|
-
|
Integral dose and null
|
Integral dose and null | Integral dose and null. Differential dose | Integral dose and null. Differential dose | Integral dose and null. Differential dose | Integral dose and null. Differential dose |
Screening
|
-
|
-
|
-
|
-
|
1 modes | 2 modes | 2 modes |
Dose indication
|
Sound | Sound and symbolic | Sound and symbolic | Sound and symbolic | Sound and symbolic | Sound and symbolic | Sound and symbolic |
Damping |
-
|
-
|
4 constant modes, 1 variable mode | 4 constant modes, 1 variable mode | 4 constant modes, 1 variable mode | 4 constant modes, 1 variable mode | 4 constant modes, 1 variable mode |
Amplitude modulation |
Saw-tooth
|
“3 : 1”
|
“1 : 1”, “2 : 1”, “3 : 1”, “4 : 1”, “5 : 1” | “1 : 1”, “2 : 1”, “3 : 1”, “4 : 1”, “5 : 1” | “1 : 1”, “2 : 1”, “3 : 1”, “4 : 1”, “5 : 1” | “1 : 1”, “2 : 1”, “3 : 1”, “4 : 1”, “5 : 1”, BEE. | “1 : 1”, “2 : 1”, “3 : 1”, “4 : 1”, “5 : 1”, BEE |
Frequency modulation | 30 - 120Hz, cycle - 8sec | 30 - 120Hz, cycle - 8sec |
30 - 120Hz, cycle - 8sec |
30 - 120Hz, cycle - 8sec, swing |
30 - 120Hz, cycle - 8sec, swing |
30 - 120Hz, cycle - 8sec, swing, 8 modes in low frequency diapason | 30 - 120Hz, cycle - 8sec, swing |
Influencing impulse frequencies | 60, 120Hz | 15, 60, 120, 350Hz | 15…350Hz | 15…350Hz | 15…350Hz | 15…350Hz 0.641..14.9 Hz |
15…350Hz |
Intensity (the number of impulses in a packet) |
1
|
1
|
1 … 8
|
1 … 8
|
1 … 8
|
1 … 8 |
1 … 8
|
The duration of gaps between impulses in a packet - Z |
-
|
-
|
200 … 1600µsec | 200 … 1600µsec | 200 … 1600µsec | 200 … 1600µsec | 200 … 1600µsec |
Power Influence | 10 … 250 units | 1 … 250 units | 1 … 250 units | 1 … 250 units | 1 … 250 units. | 1 … 250 units. | 1 … 250 units. |
Indicator | Light-emitting diodes | Graphic LCD with backlight | Graphic LCD with backlight | Graphic LCD with backlight | Graphic LCD with backlight | Graphic LCD with backlight | Graphic LCD with backlight |
Input of personal sets of parameters |
-
|
-
|
Up to 5 sets are saved. | Up to 5 sets are saved. | Up to 5 sets are saved. | Up to 5 sets are saved. | Up to 5 sets are saved. |
If you have a questions about Scenar therapy or Scenar devices, terms, please ASK.
Certifications
USA (FDA code of Federal
Regulations) : : The SCENAR device, Biofeedback-controlled electro-stimulator,
is regulated by the United States Food and Drug Administration, under 21 CFR 882.5050,
Generic Name: Device, Biofeedback, Product Code HCC, Class II exempt from 510(k)
pre-market notification according to FDA. Notice (Federal Register), Jan. 21, 1998,
p. 84) as a battery-powered, professional use device . http://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfcfr/CFRSearch.cfm?FR=882.5050
EUROPE : The SCENAR device has received a CE-mark
in Europe (CE 60906 BSI).
AUSTRALIA : The SCENAR device listed on the
Australian Register of Australian Goods (ARTG). The registration listing number
is 101783